2025-06-11 12:21:48 +00:00

601 lines
17 KiB
Python

#!/usr/bin/python3
#
# This script set fan speed and monitor power button events.
#
# Fan Speed is set by sending 0 to 100 to the MCU (Micro Controller Unit)
# The values will be interpreted as the percentage of fan speed, 100% being maximum
#
# Power button events are sent as a pulse signal to BCM Pin 4 (BOARD P7)
# A pulse width of 20-30ms indicates reboot request (double-tap)
# A pulse width of 40-50ms indicates shutdown request (hold and release after 3 secs)
#
# Additional comments are found in each function below
#
# Standard Deployment/Triggers:
# * Raspbian, OSMC: Runs as service via /lib/systemd/system/argononed.service
# * lakka, libreelec: Runs as service via /storage/.config/system.d/argononed.service
# * recalbox: Runs as service via /etc/init.d/
#
import sys
import os
import time
from threading import Thread
from queue import Queue
sys.path.append("/etc/argon/")
from argonsysinfo import *
from argonregister import *
from argonpowerbutton import *
# Initialize I2C Bus
bus = argonregister_initializebusobj()
OLED_ENABLED=False
if os.path.exists("/etc/argon/argoneonoled.py"):
import datetime
from argoneonoled import *
OLED_ENABLED=True
OLED_CONFIGFILE = "/etc/argoneonoled.conf"
UNIT_CONFIGFILE = "/etc/argonunits.conf"
# This function converts the corresponding fanspeed for the given temperature
# The configuration data is a list of strings in the form "<temperature>=<speed>"
def get_fanspeed(tempval, configlist):
for curconfig in configlist:
curpair = curconfig.split("=")
tempcfg = float(curpair[0])
fancfg = int(float(curpair[1]))
if tempval >= tempcfg:
if fancfg < 1:
return 0
elif fancfg < 25:
return 25
return fancfg
return 0
# This function retrieves the fanspeed configuration list from a file, arranged by temperature
# It ignores lines beginning with "#" and checks if the line is a valid temperature-speed pair
# The temperature values are formatted to uniform length, so the lines can be sorted properly
def load_config(fname):
newconfig = []
try:
with open(fname, "r") as fp:
for curline in fp:
if not curline:
continue
tmpline = curline.strip()
if not tmpline:
continue
if tmpline[0] == "#":
continue
tmppair = tmpline.split("=")
if len(tmppair) != 2:
continue
tempval = 0
fanval = 0
try:
tempval = float(tmppair[0])
if tempval < 0 or tempval > 100:
continue
except:
continue
try:
fanval = int(float(tmppair[1]))
if fanval < 0 or fanval > 100:
continue
except:
continue
newconfig.append( "{:5.1f}={}".format(tempval,fanval))
if len(newconfig) > 0:
newconfig.sort(reverse=True)
except:
return []
return newconfig
# Load OLED Config file
def load_oledconfig(fname):
output={}
screenduration=-1
screenlist=[]
try:
with open(fname, "r") as fp:
for curline in fp:
if not curline:
continue
tmpline = curline.strip()
if not tmpline:
continue
if tmpline[0] == "#":
continue
tmppair = tmpline.split("=")
if len(tmppair) != 2:
continue
if tmppair[0] == "switchduration":
output['screenduration']=int(tmppair[1])
elif tmppair[0] == "screensaver":
output['screensaver']=int(tmppair[1])
elif tmppair[0] == "screenlist":
output['screenlist']=tmppair[1].replace("\"", "").split(" ")
elif tmppair[0] == "enabled":
output['enabled']=tmppair[1].replace("\"", "")
except:
return {}
return output
# Load Unit Config file
def load_unitconfig(fname):
output={"temperature": "C"}
try:
with open(fname, "r") as fp:
for curline in fp:
if not curline:
continue
tmpline = curline.strip()
if not tmpline:
continue
if tmpline[0] == "#":
continue
tmppair = tmpline.split("=")
if len(tmppair) != 2:
continue
if tmppair[0] == "temperature":
output['temperature']=tmppair[1].replace("\"", "")
except:
return {}
return output
def load_fancpuconfig():
fanconfig = ["65=100", "60=55", "55=30"]
tmpconfig = load_config("/etc/argononed.conf")
if len(tmpconfig) > 0:
fanconfig = tmpconfig
return fanconfig
def load_fanhddconfig():
fanhddconfig = ["50=100", "40=55", "30=30"]
fanhddconfigfile = "/etc/argononed-hdd.conf"
if os.path.isfile(fanhddconfigfile):
tmpconfig = load_config(fanhddconfigfile)
if len(tmpconfig) > 0:
fanhddconfig = tmpconfig
else:
fanhddconfig = []
return fanhddconfig
# This function is the thread that monitors temperature and sets the fan speed
# The value is fed to get_fanspeed to get the new fan speed
# To prevent unnecessary fluctuations, lowering fan speed is delayed by 30 seconds
#
# Location of config file varies based on OS
#
def temp_check():
INITIALSPEEDVAL = 200 # ensures fan speed gets set during initialization (e.g. change settings)
argonregsupport = argonregister_checksupport(bus)
fanconfig = load_fancpuconfig()
fanhddconfig = load_fanhddconfig()
prevspeed=INITIALSPEEDVAL
while True:
# Speed based on CPU Temp
val = argonsysinfo_getcputemp()
newspeed = get_fanspeed(val, fanconfig)
# Speed based on HDD Temp
val = argonsysinfo_getmaxhddtemp()
tmpspeed = get_fanspeed(val, fanhddconfig)
# Use faster fan speed
if tmpspeed > newspeed:
newspeed = tmpspeed
if prevspeed == newspeed:
time.sleep(30)
continue
elif newspeed < prevspeed and prevspeed != INITIALSPEEDVAL:
# Pause 30s before speed reduction to prevent fluctuations
time.sleep(30)
prevspeed = newspeed
try:
if newspeed > 0:
# Spin up to prevent issues on older units
argonregister_setfanspeed(bus, 100, argonregsupport)
# Set fan speed has sleep
argonregister_setfanspeed(bus, newspeed, argonregsupport)
time.sleep(30)
except IOError:
time.sleep(60)
#
# This function is the thread that updates OLED
#
def display_loop(readq):
weekdaynamelist = ["Mon", "Tue", "Wed", "Thu", "Fri", "Sat", "Sun"]
monthlist = ["JAN", "FEB", "MAR", "APR", "MAY", "JUN", "JUL", "AUG", "SEP", "OCT", "NOV", "DEC"]
oledscreenwidth = oled_getmaxX()
fontwdSml = 6 # Maps to 6x8
fontwdReg = 8 # Maps to 8x16
stdleftoffset = 54
temperature="C"
tmpconfig=load_unitconfig(UNIT_CONFIGFILE)
if "temperature" in tmpconfig:
temperature = tmpconfig["temperature"]
screensavermode = False
screensaversec = 120
screensaverctr = 0
screenenabled = ["clock", "ip"]
prevscreen = ""
curscreen = ""
screenid = 0
screenjogtime = 0
screenjogflag = 0 # start with screenid 0
cpuusagelist = []
curlist = []
tmpconfig=load_oledconfig(OLED_CONFIGFILE)
if "screensaver" in tmpconfig:
screensaversec = tmpconfig["screensaver"]
if "screenduration" in tmpconfig:
screenjogtime = tmpconfig["screenduration"]
if "screenlist" in tmpconfig:
screenenabled = tmpconfig["screenlist"]
if "enabled" in tmpconfig:
if tmpconfig["enabled"] == "N":
screenenabled = []
while len(screenenabled) > 0:
if len(curlist) == 0 and screenjogflag == 1:
# Reset Screen Saver
screensavermode = False
screensaverctr = 0
# Update screen info
screenid = screenid + screenjogflag
if screenid >= len(screenenabled):
screenid = 0
prevscreen = curscreen
curscreen = screenenabled[screenid]
if screenjogtime == 0:
# Resets jogflag (if switched manually)
screenjogflag = 0
else:
screenjogflag = 1
needsUpdate = False
if curscreen == "cpu":
# CPU Usage
if len(curlist) == 0:
try:
if len(cpuusagelist) == 0:
cpuusagelist = argonsysinfo_listcpuusage()
curlist = cpuusagelist
except:
curlist = []
if len(curlist) > 0:
oled_loadbg("bgcpu")
# Display List
yoffset = 0
tmpmax = 4
while tmpmax > 0 and len(curlist) > 0:
curline = ""
tmpitem = curlist.pop(0)
curline = tmpitem["title"]+": "+str(tmpitem["value"])+"%"
oled_writetext(curline, stdleftoffset, yoffset, fontwdSml)
oled_drawfilledrectangle(stdleftoffset, yoffset+12, int((oledscreenwidth-stdleftoffset-4)*tmpitem["value"]/100), 2)
tmpmax = tmpmax - 1
yoffset = yoffset + 16
needsUpdate = True
else:
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "storage":
# Storage Info
if len(curlist) == 0:
try:
tmpobj = argonsysinfo_listhddusage()
for curdev in tmpobj:
curlist.append({"title": curdev, "value": argonsysinfo_kbstr(tmpobj[curdev]['total']), "usage": int(100*tmpobj[curdev]['used']/tmpobj[curdev]['total']) })
#curlist = argonsysinfo_liststoragetotal()
except:
curlist = []
if len(curlist) > 0:
oled_loadbg("bgstorage")
yoffset = 16
tmpmax = 3
while tmpmax > 0 and len(curlist) > 0:
tmpitem = curlist.pop(0)
# Right column first, safer to overwrite white space
oled_writetextaligned(tmpitem["value"], 77, yoffset, oledscreenwidth-77, 2, fontwdSml)
oled_writetextaligned(str(tmpitem["usage"])+"%", 50, yoffset, 74-50, 2, fontwdSml)
tmpname = tmpitem["title"]
if len(tmpname) > 8:
tmpname = tmpname[0:8]
oled_writetext(tmpname, 0, yoffset, fontwdSml)
tmpmax = tmpmax - 1
yoffset = yoffset + 16
needsUpdate = True
else:
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "raid":
# Raid Info
if len(curlist) == 0:
try:
tmpobj = argonsysinfo_listraid()
curlist = tmpobj['raidlist']
except:
curlist = []
if len(curlist) > 0:
oled_loadbg("bgraid")
tmpitem = curlist.pop(0)
oled_writetextaligned(tmpitem["title"], 0, 0, stdleftoffset, 1, fontwdSml)
oled_writetextaligned(tmpitem["value"], 0, 8, stdleftoffset, 1, fontwdSml)
oled_writetextaligned(argonsysinfo_kbstr(tmpitem["info"]["size"]), 0, 56, stdleftoffset, 1, fontwdSml)
if len(tmpitem['info']['state']) > 0:
oled_writetext( tmpitem['info']['state'], stdleftoffset, 8, fontwdSml )
if len(tmpitem['info']['rebuildstat']) > 0:
oled_writetext("Rebuild:" + tmpitem['info']['rebuildstat'], stdleftoffset, 16, fontwdSml)
# TODO: May need to use different method for each raid type (i.e. check raidlist['raidlist'][raidctr]['value'])
#oled_writetext("Used:"+str(int(100*tmpitem["info"]["used"]/tmpitem["info"]["size"]))+"%", stdleftoffset, 24, fontwdSml)
oled_writetext("Active:"+str(int(tmpitem["info"]["active"]))+"/"+str(int(tmpitem["info"]["devices"])), stdleftoffset, 32, fontwdSml)
oled_writetext("Working:"+str(int(tmpitem["info"]["working"]))+"/"+str(int(tmpitem["info"]["devices"])), stdleftoffset, 40, fontwdSml)
oled_writetext("Failed:"+str(int(tmpitem["info"]["failed"]))+"/"+str(int(tmpitem["info"]["devices"])), stdleftoffset, 48, fontwdSml)
needsUpdate = True
else:
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "ram":
# RAM
try:
oled_loadbg("bgram")
tmpraminfo = argonsysinfo_getram()
oled_writetextaligned(tmpraminfo[0], stdleftoffset, 8, oledscreenwidth-stdleftoffset, 1, fontwdReg)
oled_writetextaligned("of", stdleftoffset, 24, oledscreenwidth-stdleftoffset, 1, fontwdReg)
oled_writetextaligned(tmpraminfo[1], stdleftoffset, 40, oledscreenwidth-stdleftoffset, 1, fontwdReg)
needsUpdate = True
except:
needsUpdate = False
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "temp":
# Temp
try:
oled_loadbg("bgtemp")
hddtempctr = 0
maxcval = 0
mincval = 200
# Get min/max of hdd temp
hddtempobj = argonsysinfo_gethddtemp()
for curdev in hddtempobj:
if hddtempobj[curdev] < mincval:
mincval = hddtempobj[curdev]
if hddtempobj[curdev] > maxcval:
maxcval = hddtempobj[curdev]
hddtempctr = hddtempctr + 1
cpucval = argonsysinfo_getcputemp()
if hddtempctr > 0:
alltempobj = {"cpu": cpucval,"hdd min": mincval, "hdd max": maxcval}
# Update max C val to CPU Temp if necessary
if maxcval < cpucval:
maxcval = cpucval
displayrowht = 8
displayrow = 8
for curdev in alltempobj:
if temperature == "C":
# Celsius
tmpstr = str(alltempobj[curdev])
if len(tmpstr) > 4:
tmpstr = tmpstr[0:4]
else:
# Fahrenheit
tmpstr = str(32+9*(alltempobj[curdev])/5)
if len(tmpstr) > 5:
tmpstr = tmpstr[0:5]
if len(curdev) <= 3:
oled_writetext(curdev.upper()+": "+ tmpstr+ chr(167) +temperature, stdleftoffset, displayrow, fontwdSml)
else:
oled_writetext(curdev.upper()+":", stdleftoffset, displayrow, fontwdSml)
oled_writetext(" "+ tmpstr+ chr(167) +temperature, stdleftoffset, displayrow+displayrowht, fontwdSml)
displayrow = displayrow + displayrowht*2
else:
maxcval = cpucval
if temperature == "C":
# Celsius
tmpstr = str(cpucval)
if len(tmpstr) > 4:
tmpstr = tmpstr[0:4]
else:
# Fahrenheit
tmpstr = str(32+9*(cpucval)/5)
if len(tmpstr) > 5:
tmpstr = tmpstr[0:5]
oled_writetextaligned(tmpstr+ chr(167) +temperature, stdleftoffset, 24, oledscreenwidth-stdleftoffset, 1, fontwdReg)
# Temperature Bar: 40C is min, 80C is max
maxht = 21
barht = int(maxht*(maxcval-40)/40)
if barht > maxht:
barht = maxht
elif barht < 1:
barht = 1
oled_drawfilledrectangle(24, 20+(maxht-barht), 3, barht, 2)
needsUpdate = True
except:
needsUpdate = False
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "ip":
# IP Address
try:
oled_loadbg("bgip")
oled_writetextaligned(argonsysinfo_getip(), 0, 8, oledscreenwidth, 1, fontwdReg)
needsUpdate = True
except:
needsUpdate = False
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "logo1v5":
# Logo
try:
oled_loadbg("logo1v5")
needsUpdate = True
except:
needsUpdate = False
# Next page due to error/no data
screenjogflag = 1
else:
try:
oled_loadbg("bgtime")
# Date and Time HH:MM
curtime = datetime.datetime.now()
# Month/Day
outstr = str(curtime.day).strip()
if len(outstr) < 2:
outstr = " "+outstr
outstr = monthlist[curtime.month-1]+outstr
oled_writetextaligned(outstr, stdleftoffset, 8, oledscreenwidth-stdleftoffset, 1, fontwdReg)
# Day of Week
oled_writetextaligned(weekdaynamelist[curtime.weekday()], stdleftoffset, 24, oledscreenwidth-stdleftoffset, 1, fontwdReg)
# Time
outstr = str(curtime.minute).strip()
if len(outstr) < 2:
outstr = "0"+outstr
outstr = str(curtime.hour)+":"+outstr
if len(outstr) < 5:
outstr = "0"+outstr
oled_writetextaligned(outstr, stdleftoffset, 40, oledscreenwidth-stdleftoffset, 1, fontwdReg)
needsUpdate = True
except:
needsUpdate = False
# Next page due to error/no data
screenjogflag = 1
if needsUpdate == True:
if screensavermode == False:
# Update screen if not screen saver mode
oled_power(True)
oled_flushimage(prevscreen != curscreen)
oled_reset()
timeoutcounter = 0
while timeoutcounter<screenjogtime or screenjogtime == 0:
qdata = ""
if readq.empty() == False:
qdata = readq.get()
if qdata == "OLEDSWITCH":
# Trigger screen switch
screenjogflag = 1
# Reset Screen Saver
screensavermode = False
screensaverctr = 0
break
elif qdata == "OLEDSTOP":
# End OLED Thread
display_defaultimg()
return
else:
screensaverctr = screensaverctr + 1
if screensaversec <= screensaverctr and screensavermode == False:
screensavermode = True
oled_fill(0)
oled_reset()
oled_power(False)
if timeoutcounter == 0:
# Use 1 sec sleep get CPU usage
cpuusagelist = argonsysinfo_listcpuusage(1)
else:
time.sleep(1)
timeoutcounter = timeoutcounter + 1
if timeoutcounter >= 60 and screensavermode == False:
# Refresh data every minute, unless screensaver got triggered
screenjogflag = 0
break
display_defaultimg()
def display_defaultimg():
# Load default image
#oled_power(True)
#oled_loadbg("bgdefault")
#oled_flushimage()
oled_fill(0)
oled_reset()
if len(sys.argv) > 1:
cmd = sys.argv[1].upper()
if cmd == "SHUTDOWN":
# Signal poweroff
argonregister_signalpoweroff(bus)
elif cmd == "FANOFF":
# Turn off fan
argonregister_setfanspeed(bus,0)
if OLED_ENABLED == True:
display_defaultimg()
elif cmd == "SERVICE":
# Starts the power button and temperature monitor threads
try:
ipcq = Queue()
if len(sys.argv) > 2:
cmd = sys.argv[2].upper()
if cmd == "OLEDSWITCH":
t1 = Thread(target = argonpowerbutton_monitorswitch, args =(ipcq, ))
else:
t1 = Thread(target = argonpowerbutton_monitor, args =(ipcq, ))
t2 = Thread(target = temp_check)
if OLED_ENABLED == True:
t3 = Thread(target = display_loop, args =(ipcq, ))
t1.start()
t2.start()
if OLED_ENABLED == True:
t3.start()
ipcq.join()