#!/usr/bin/python3
|
||||
|
||||
import time
|
||||
import os
|
||||
|
||||
UPS_LOGFILE="/dev/shm/upslog.txt"
|
||||
#UPS_DEVFILE="/dev/argonbatteryicon"
|
||||
|
||||
def notifymessage(message, iscritical):
|
||||
wftype="notify"
|
||||
if iscritical:
|
||||
wftype="critical"
|
||||
os.system("export SUDO_UID=1000; wfpanelctl "+wftype+" \""+message+"\"")
|
||||
os.system("export DISPLAY=:0.0; lxpanelctl notify \""+message+"\"")
|
||||
|
||||
try:
|
||||
outobj = {}
|
||||
#os.system("insmod /etc/argon/ups/argonbatteryicon.ko")
|
||||
prevnotifymsg=""
|
||||
|
||||
tmp_battery = 100
|
||||
tmp_charging = 1
|
||||
|
||||
device_battery = -1
|
||||
device_charging = -1
|
||||
|
||||
while True:
|
||||
try:
|
||||
# Load status
|
||||
fp = open(UPS_LOGFILE, "r")
|
||||
logdata = fp.read()
|
||||
alllines = logdata.split("\n")
|
||||
ctr = 0
|
||||
while ctr < len(alllines):
|
||||
tmpval = alllines[ctr].strip()
|
||||
curinfo = tmpval.split(":")
|
||||
if len(curinfo) > 1:
|
||||
tmpattrib = curinfo[0].lower().split(" ")
|
||||
# The rest are assumed to be value
|
||||
outobj[tmpattrib[0]] = tmpval[(len(curinfo[0])+1):].strip()
|
||||
ctr = ctr + 1
|
||||
|
||||
# Map to data
|
||||
try:
|
||||
statuslist = outobj["power"].lower().split(" ")
|
||||
if statuslist[0] == "battery":
|
||||
tmp_charging = 0
|
||||
else:
|
||||
tmp_charging = 1
|
||||
tmp_battery = int(statuslist[1].replace("%",""))
|
||||
except:
|
||||
tmp_charging = device_charging
|
||||
tmp_battery = device_battery
|
||||
|
||||
# Update module data if changed
|
||||
if tmp_charging != device_charging or tmp_battery!=device_battery:
|
||||
device_charging = tmp_charging
|
||||
device_battery = tmp_battery
|
||||
|
||||
# No longer using default battery indicator
|
||||
#try:
|
||||
# with open(UPS_DEVFILE, 'w') as f:
|
||||
# f.write("capacity = "+str(device_battery)+"\ncharging = "+str(device_charging)+"\n")
|
||||
#except Exception as e:
|
||||
# pass
|
||||
|
||||
curnotifymsg = ""
|
||||
curnotifycritical=False
|
||||
|
||||
if tmp_charging:
|
||||
if "Shutting Down" in prevnotifymsg:
|
||||
os.system("shutdown -c ""Charging, shutdown cancelled.""")
|
||||
|
||||
if tmp_battery > 99:
|
||||
curnotifymsg="Fully Charged"
|
||||
elif tmp_charging:
|
||||
curnotifymsg="Charging"
|
||||
else:
|
||||
if tmp_battery > 50:
|
||||
curnotifymsg="Battery Mode"
|
||||
elif tmp_battery > 20:
|
||||
curnotifymsg="50%% Battery"
|
||||
elif tmp_battery > 10:
|
||||
curnotifymsg="20%% Battery"
|
||||
elif tmp_battery > 5:
|
||||
#curnotifymsg="Low Battery"
|
||||
curnotifymsg="Low Battery: The device may power off automatically soon."
|
||||
curnotifycritical=True
|
||||
else:
|
||||
curnotifymsg="CRITICAL BATTERY: Shutting Down in 1 minute"
|
||||
curnotifycritical=True
|
||||
|
||||
|
||||
if prevnotifymsg != curnotifymsg:
|
||||
notifymessage(curnotifymsg, curnotifycritical)
|
||||
if tmp_battery <= 5 and tmp_charging != 0:
|
||||
os.system("shutdown +1 """+curnotifymsg+".""")
|
||||
|
||||
prevnotifymsg = curnotifymsg
|
||||
|
||||
except OSError:
|
||||
pass
|
||||
time.sleep(60)
|
||||
except:
|
||||
pass
|
||||
|
||||